Active Differential Probe CE-DP1500V1.1
Our 1.5 GHz Active Differential Probe is portable, ergonomic, and high-performing. Perfect for precise measurements in lab or on the go.
$998 USD
Advantages of an Active Differential Probe
Unlike passive probes, active differential probes amplify signals and improve measurement fidelity in high-speed circuits. The CE-DP1500V1.1 offers great versatility by accurately capturing differential signals in complex systems:
Probe Type: Active differential probe, ideal for high-speed circuits and variable impedances, supporting both differential and single-ended measurements.
Attenuation Ratio: Features a native 1:1 ratio, which can be extended to 10:1 using a 10x divider adapter.
Frequency Range: Capable of measuring signals from DC up to >1.5 GHz (usable for high-frequency needs).
Power Supply: Convenient universal USB power supply compatible with different instruments.
Applications
Ideal for
Development and debugging of analog and digital systems. Improves noise rejection.
Active Probe for
High frequency applications. Characterization of components and systems.
Can be Used for
R&D and educational applications. In production . EMC/EMI measurements
Technical Specifications
| Inputs And Outputs | |
|---|---|
| Pogo Pins Differential Input | 2 |
| USB-connector for Power (USB -A) | 5V – 500mA |
| SMA Connector | RF Signal |
| Technical and Electrical Features | |
|---|---|
| Bandwidth [1] | >1.5 GHz |
| Rise Time | <0.5 ns |
| Input Resistance | 2 MΩ |
| Input Capacitance | <1.2 pF |
| Input Dynamic Range | ±2 V |
| Input Common mode | 0 V |
| (DC) to 1 GHz Range | ±2 V > 0 |
| Common Mode Rejection Ratio | >45 dB @ 1 MHz |
| DC Attenuation | 1:1 ±2% |
| Divider by 10 Adapter | 1:10 |
| Input Noise | 8 mVpp |
| Propagation Delay | 7 ns |
| Maximum Operational Voltage (Recommended) | 1 Vpp |
| Absolute Maximum Voltage Rating [2] | 10 Vpp |
| Electrostatic Protection (HBM) | >8 kV |
[1] Normal/linear operation above 1.2 GHz, but USABLE up to 3 GHz
[2] The maximum allowable input is 10 Vpp. Exceeding this value may permanently damage the probe’s active input stage.
For best accuracy and linearity, it is recommended to operate at or below 1 Vpp.
[3] Installation Category (Overvoltage Category) I (CAT I): This instrument is intended for signal-level measurements on electronic, telecommunications, and special equipment circuits that are not directly connected to mains power. Transient overvoltages in these environments are lower than those encountered in Installation Category II.
Adapters
Divider by 10 Adapter
Solder Adapter
Flex Adapter
Included Accessories
Pogo Pins
Test Leads MicroLead Male-Female Set ( A Pair) 1mm (diameter pin), red and black 10 cm
Illuminated tip
Test Leads MicroLead Male-Male 1mm(diameter pin), red and black 10 cm
Microclip (Red & Black)
Needle Tip
Hex key & screws
Freehand Probe Holder
Cap